云计算百科
云计算领域专业知识百科平台

Dell服务器中Lsiutil命令常见使用

  • Download firmware (update the FLASH)

  • Download/erase BIOS and/or FCode (update the FLASH)

  • Scan for devices

  • Change IOC settings (interrupt coalescing)

  • Change SAS IO Unit settings

  • Display attached devices

  • Diagnostics

  • RAID actions

  • Reset bus

  • Reset target

  • Display operating system names for devices

  • Concatenate SAS firmware and NVDATA files

  • Show non-default settings

  • Restore default settings

  • Show board manufacturing information

  • Reset SAS link, HARD RESET

  • Reset SAS link

  • Reset port

  • e Enable expert mode in menus

    p Enable paged mode

    w Enable logging

    Main menu, select an option: [1-99 or e/p/w or 0 to quit] 69 — 查看Raid 卡的信息板子名称【SAS6IR】

    Seg/Bus/Dev/Fun Board Name Board Assembly Board Tracer

    0 2 0 0 SAS6IR

    Main menu, select an option: [1-99 or e/p/w or 0 to quit] 8 —扫描硬盘设备并打印设备状态

    SAS1068E’s links are 3.0 G, 3.0 G, down, down, off, off, off, off

    B___T___L Type Vendor Product Rev SASAddress PhyNum

    0 0 0 Disk Dell VIRTUAL DISK 1028

    0 8 0 EnclServ DP BACKPLANE 1.07 5942b0b02dcf1a00 8

    Hidden RAID Devices:

    B___T Device Vendor Product Rev SASAddress PhyNum

    0 1 PhysDisk 0 SEAGATE ST3600057SS ES62 5000c50023c4b95d 1

    0 9 PhysDisk 1 SEAGATE ST3600057SS ES62 5000c50023c4bd95 0

    【查看Raid 状态】: 进入21 选项:

    Main menu, select an option: [1-99 or e/p/w or 0 to quit] 21

  • Show volumes

  • Show physical disks

  • Get volume state

  • Wait for volume resync to complete

  • Replace physical disk

  • Disable drive firmware update mode

  • Enable drive firmware update mode

  • Create volume

  • Delete volume

  • Change volume settings

  • Change volume name

  • Create hot spare

  • Reset port

  • e Enable expert mode in menus

    p Enable paged mode

    w Enable logging

    RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 2 —查看设备在线状态

    1 volume is active, 2 physical disks are active

    PhysDisk 0 is Bus 0 Target 1

    PhysDisk State: online

    PhysDisk Size 572325 MB, Inquiry Data: SEAGATE ST3600057SS ES62

    Warning, page length in reply does not match page length in buffer

    (9 vs. 15)

    PhysDisk 1 is Bus 0 Target 9

    PhysDisk State: online

    PhysDisk Size 572325 MB, Inquiry Data: SEAGATE ST3600057SS ES62

    Warning, page length in reply does not match page length in buffer

    (9 vs. 15)

    注意,因为我的两块硬盘做得是Raid 0 ,如果你的磁盘做得是Raid 1 可以通过 【4. Wait for volume resync to complete】两块硬盘的同步状态

    RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 4 —我的是Raid 0

    Volume 0 State: optimal, enabled

    以下几个菜单可以在线创建阵列!

  • Create volume

  • Delete volume

  • Change volume settings

  • Change volume name

  • Create hot spare

  • #注意以上所有的退出使用阿拉数字零

    3、非交互方式查看SAS 6/iR卡信息

    如果你觉得上面的菜单选项比较麻烦,你也可以使用命令行模式完成!如下:

    lsiutil –p1 –a 8,21,4,0,0

    -p1 指1 MPT Port found

    -a 指你选择的菜单号,并使用逗号分开.

    0表示退出参数——即进入几个菜单,就是用几个0 做退出!

    [root@k]# ./lsiutil -p1 -a 8,21,4,0,0

    LSI Logic MPT Configuration Utility, Version 1.56, March 19, 2008

    1 MPT Port found

    Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC

  • /proc/mpt/ioc0 LSI Logic SAS1068E B3 105 00192f00 0
  • Main menu, select an option: [1-99 or e/p/w or 0 to quit] 8

    SAS1068E’s links are 3.0 G, 3.0 G, down, down, off, off, off, off B___T___L Type Vendor Product Rev SASAddress PhyNum

    0 0 0 Disk Dell VIRTUAL DISK 1028

    0 8 0 EnclServ DP BACKPLANE 1.07 5942b0b02dcf1a00 8

    Hidden RAID Devices:

    B___T Device Vendor Product Rev SASAddress PhyNum

    0 1 PhysDisk 0 SEAGATE ST3600057SS ES62 5000c50023c4b95d 1

    0 9 PhysDisk 1 SEAGATE ST3600057SS ES62 5000c50023c4bd95 0

    Main menu, select an option: [1-99 or e/p/w or 0 to quit] 21

    RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 4

    Volume 0 State: optimal, enabled

    RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 0

    Main menu, select an option: [1-99 or e/p/w or 0 to quit] 0

    ## 常用命令

    ./lsiutil -p 1 -a 20,12,0,0 查看硬盘计数器

    ./lsiutil -p 1 -a 21,1,0,0,0 查看逻辑卷状态

    ![在这里插入图片描述](https://www.wsisp.com/helps/wp-content/uploads/2025/04/20250418110728-68023270873d5.png?x-oss-process=image/watermark,type_ZmFuZ3poZW5naGVpdGk,shadow_10,text_aHR0cHM6Ly9ibG9nLmNzZG4ubmV0L3FxXzQwOTA3OTc3,size_16,color_FFFFFF,t_70)

    ./lsiutil -p 1 -a 21,2,0,0,0 查看物理硬盘状态 状态值 对应含义 PhysDisk 0 is Bus 0 Target 3 编号 PhysDisk State: online 状态 Error Count 13, Last Error: Command = 28h, Key = 3, ASC/ASCQ = 11h/00h 错误计数器,大于0的话,就需要引起关注

    ![在这里插入图片描述](https://www.wsisp.com/helps/wp-content/uploads/2025/04/20250418110728-680232709c0bb.png?x-oss-process=image/watermark,type_ZmFuZ3poZW5naGVpdGk,shadow_10,text_aHR0cHM6Ly9ibG9nLmNzZG4ubmV0L3FxXzQwOTA3OTc3,size_16,color_FFFFFF,t_70)

    ./lsiutil -p 1 -i –s 显示端口1的设置和连接的设备

    ./lsiutil –s 显示所有端口上连接的设备

    ./lsiutil -p 2 -l 1 强制HBA卡端口2连接速度为1Gb

    ./lsiutil –p1 –a 21,1,0,0,0 和上边菜单操作一样,只不过不用手动去选择菜单项了

    ./lsiutil -p 1 -i –s 显示端口1的设置和连接的设备

    ./lsiutil –s 显示所有端口上连接的设备

    ./lsiutil -p 2 -l 1 强制HBA卡端口2连接速度为1Gb

    ./lsiutil -p 1 -a 21,1,0,0,0 — 查看逻辑卷状态 状态值 对应含义 Volume State: optimal, enabled 逻辑卷健康状况 Volume draws from Hot Spare Pools: 0 是否有热备 Volume Size 139392 MB, 2 Members 由几块硬盘组成 Primary is PhysDisk 1 (Bus 0 Target 9) 物理硬盘1 Secondary is PhysDisk 0 (Bus 0 Target 3) 物理硬盘0

    ./lsiutil.x86_64 -p1 -a 8,21,4,0,0

    ![在这里插入图片描述](https://www.wsisp.com/helps/wp-content/uploads/2025/04/20250418110728-68023270acefc.png?x-oss-process=image/watermark,type_ZmFuZ3poZW5naGVpdGk,shadow_10,text_aHR0cHM6Ly9ibG9nLmNzZG4ubmV0L3FxXzQwOTA3OTc3,size_16,color_FFFFFF,t_70)

    ## 扩展

    ## 常用PC服务器阵列卡

    通常,我们使用的DELL/HP/IBM三家的机架式PC级服务器阵列卡是从LSI的卡OEM出来的,DELL和IBM两家的阵列卡原生程度较高,没有做太多封装,可以用原厂提供的阵列卡管理工具进行监控;而HP的阵列卡一般都做过封装了,因此需要使用自身特有的管理工具来监控。

    **本文以几种常用的阵列卡为例,展示其阵列卡及硬盘监控的方法。**
    **DELL SAS 6/iR卡**,全称LSI Logic SAS1068E,只支持RAID 0, RAID 1, RAID 1+0, 不支持RAID 5等高级RAID特性,不支持阵列卡电池。
    **DELL PERC PERC H700卡**,全称LSI Logic MegaRAID SAS 2108,支持各种RAID级别及高级特性,可选配阵列卡电池。
    **DELL PERC H310 Mini卡** ,全称LSI Logic / Symbios Logic MegaRAID SAS 2008,支持常见RAID级别,不支持高级RAID特性,不支持阵列卡电池。
    **IBM ServeRAID M5014 SAS/SATA Controller卡**,全称LSI Logic / Symbios Logic MegaRAID SAS 2108,支持各种RAID级别及高级特性,可选配阵列卡电池。
    **IBM ServeRAID-MR10i SAS/SATA Controller卡**,全称LSI Logic / Symbios Logic MegaRAID SAS 1078,支持常见RAID级别,不支持高级RAID特性,可选配阵列卡电池,这个卡其实和DELL的PERC 6/i卡是一样的,都是基于LSI MegaRAID SAS 1078基础上OEM出来的。

    ## hpacucli工具

    hpacucli工具查看阵列、硬盘、电池信息,其实就只要一条指令:
    hpacucli ctrl all show config detail — 查看阵列详细信息、配置

    #hpacucli工具查看阵列、硬盘、电池信息,其实就只要一条指令:

    hpacucli ctrl all show config detail — 查看阵列详细信息、配置

    状态值 对应含义 Controller Status: OK 阵列卡状态 Firmware Version: 1.18 firmware版本,太低了建议升级,以提高稳定性及性能 Cache Board Present: True 是否配备了cache模块 Cache Status: OK cache模块状态 Cache Ratio: 100% Read / 0% Write cache策略,此处只有读cache,不用于写cache,因为没有bbu电池,见下方结果 Drive Write Cache: Disabled 关闭磁盘cache Total Cache Size: 256 MB cache大小 Total Cache Memory Available: 208 MB 实际可用cache大小,和理论cache大小不一样,说明cache模块可能有问题 No-Battery Write Cache: Disabled 关闭FORCEWB策略 Battery/Capacitor Count: 0 阵列卡BBU电池数量为0,也就是没有BBU模块 Battery/Capacitor Status: Failed (Replace Batteries) 阵列卡BBU电池状态,这里显示是错误状态,需要及时更换 Array: A 第一个乌列阵列,编号从A开始,依次是A、B、C Status: OK 物理阵列状态 Logical Drive: 1 第一个逻辑卷,编号从1开始 Fault Tolerance: RAID 5 第一个逻辑卷的阵列级别 Status: OK 第一个逻辑卷状态 Caching: Enabled 第一个逻辑卷是否启用了cache策略 physicaldrive 1I:1:1 第一块物理硬盘,编号从1开始 Status: OK 第一块物理硬盘状态 Firmware Revision: HPDA 第一块物理硬盘firmware,如果太低,也需要及时升级,HP的硬盘每个批次都有不同的firmware

    ![在这里插入图片描述](https://www.wsisp.com/helps/wp-content/uploads/2025/04/20250418110728-68023270c3333.png?x-oss-process=image/watermark,type_ZmFuZ3poZW5naGVpdGk,shadow_10,text_aHR0cHM6Ly9ibG9nLmNzZG4ubmV0L3FxXzQwOTA3OTc3,size_16,color_FFFFFF,t_70)
    ![在这里插入图片描述](https://www.wsisp.com/helps/wp-content/uploads/2025/04/20250418110728-68023270de24e.png)

    参考链接 :

    https://imysql.com/2014/09/11/pc-server-raid-controller-disk-health-monitoring.shtml

    https://blog.csdn.net/cnbird2008/article/details/6968107
    https://blog.51cto.com/cxj632840815/1339684

    Dell服务器MegaCli命令只返回Exit Code: 0x00问题分析 :https://www.cnblogs.com/fjping0606/p/4885905.html